CTP Room Environment Requirements:
       1.  Load-bearing requirements:
            The weight of whole devices are about 2 tons, CTP machine is about 1-1.5 tons, the ground foundation needs to be compacted.
       2.  Environment requirements:
  •         Temperature: 20 - 25 oC, the better temperature for Insun CTP is 22 - 24 oC.
  •         Relative Humidity: 40% - 80%
       3.  Power Supply: AC220 – 230, 50 – 60 Hz, 10KW
            UPS: 6KW, Single-phase
       4.  The room must be ventilation, shockproof, clean, to avoid direct sunlight. The temperature and RH must be adjustable, no strong magnetic interference equipment. There is running water and sewer in the room, the outside diameter of running water pipe is φ20-φ22, with enough pressure, the waste water in the sewer must be smooth to flow out. There is an independent ventilation system, the air must to be filtered, the amount of the clean air must be more than 10 times of the room per hour.
      